About 12V-12AH UPS Battery
12V-12AH UPS Battery has high performance, high discharge design, wide operating temperature range, and long expected service life. It controls the fluctuations that may occur in the electrical network. A UPS is an uninterruptible power supply, also known as a backup battery. It provides a constant voltage and uninterruptible frequency of power. Its main components are an energy storage device and an inverter. The offered 12V-12AH UPS Battery is made for easy installation and use wherever needed.
Product Details
|
Usage/Application
|
UPS
|
|
Brand
|
Excel
|
|
Voltage
|
12V
|
|
Type of Battery
|
Solar Battery
|
|
Power Source
|
Solar
|
|
Current
|
24 Amp
|
High Reliability and LongevityDesigned for long-term dependability, this UPS battery offers a design life of five years and a shelf life of up to one year without recharging if stored at 25C. Its low self-discharge rate ensures consistent backup power without frequent maintenance. Robust ABS plastic construction enhances durability, making the battery suitable for demanding environments.
Advanced Charging and Safety FeaturesThe battery operates safely within recommended charge and discharge voltages: 13.5V-13.8V for charging, 10.5V as the discharge cut-off. It supports maximum charging currents up to 3.6A, featuring low internal resistance for efficient energy flow. Terminal options (T1/T2 Faston) make connections straightforward and secure, minimizing downtime during replacements or installations.
Versatile Application Across IndustriesThis 12V-12AH battery is widely used in UPS systems, emergency lighting, security systems, and telecom equipment in India. Its versatility and stable performance under 0%-90% humidity (non-condensing) conditions allow it to meet a variety of back-up power needs, delivering peace of mind for homes, offices, and industrial settings alike.
FAQs of 12V-12AH UPS Battery:
Q: How do I correctly install the 12V-12AH UPS battery in my system?
A: To install the battery, use the compatible T1 or T2 Faston terminals for secure electrical connections. Make sure the UPS unit is powered off before installing, and carefully align the terminals to their matching connectors. Double-check polarity before switching the system on.
Q: What are the recommended charging parameters for optimal battery performance?
A: For best results, charge the battery at 13.5V13.8V under standby use or 14.4V15.0V during cycle use. Ensure the charging current does not exceed 3.6A to avoid damaging the battery and to preserve its design life.
Q: When should I recharge the battery during prolonged storage?
A: If stored at 25C, the battery can be kept for up to one year without needing a recharge. If stored for longer, recharge the battery before use to regain optimal performance and longevity.
Q: Where is this battery commonly utilized in India?
A: The 12V-12AH UPS battery is widely used in uninterruptible power supplies, security alarm systems, emergency lighting, telecommunications equipment, and other electronic applications that require reliable backup power.
Q: What benefits does the ABS plastic container provide?
A: The ABS plastic container enhances safety and durability, providing effective insulation and protection against physical impacts, heat, and chemical exposure, making it suitable for both industrial and residential environments.
Q: How does the batterys self-discharge rate impact maintenance requirements?
A: With a self-discharge rate below 3% per month at 25C, the battery requires minimal maintenance during storage, reducing the need for frequent recharging and ensuring power availability when needed.